Property Inspection Report
|
||||||||
Final Analysis Home Inspections 1385 Fordham Dr. Ste. 160, Virginia Beach VA 23464 |
||||||||
Prepared exclusively for removed for privacy |
||||||||
xxxx Larimar St Virginia Beach VA 23462 |
||||||||
|
||||||||
Report ID:
060415 |
||||||||
Inspection Date:
6/4/2015 |
||||||||
Inspected By:Adam Comeau
|
||||||||
757.495.2300 |
||||||||
Date: 6/4/2015 | Time: 01:00 PM | Report ID: Albright060415 |
Property: xxxx Larimar Virginia Beach VA 23462 |
Customer: removed for privacy |
Real Estate Professional: Sharon Milligan All Pros Realty |
Type of Inspection: Home Buyers inspection | Inspection Restrictions/limitations: None |
|
General inspection accessibility: Vaccant, Unoccupied | All Utility services are on?: Yes | In Attendance: Listing agent |
Type of building: Townhome | Square Feet of conditioned space: 1,588 | Age of building (year built): 2009 |
# of Bedrooms: 3 Bedrooms | # of Bathrooms: 2 bathrooms | Temperature during inspection: 73 |
Weather: Cloudy, Light Rain | Ground/Soil surface condition: Wet | Garage: Attached, 1 car |
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it is satisfactory and appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit does not exists in this home or building.
Information & Disclosures (ID) = Important information you should know about this house or building including, disclosures, alerts, advisories and warnings about typical conditions or circumstances for this home. Not necessarily something abnormal or unusual but critical information that may pose significant concern for health risk, environmental safety or additional cost. These items will be indicated with an Orange Flag
Repair or Replace (RR) = The item, component or unit is not functioning as intended, defective, broken or otherwise needs further inspection and evaluation by a qualified contractor. Items, components or units that should be repaired, replaced or corrected. These will be indicated with a Red Flag
Inspection standards: This inspection was completed in compliance with the professional standards of practice set forth by the American Society of Home inspectors (ASHI)
Purpose and Objective: This inspection is not technically exhaustive and can not be conclusive of every detail. The primary objective of this building inspection is to identify and report MATERIAL DEFECTS. Material Defects are defined as a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material defect. Normal wear and tear, maintenance typical defects or deficiencies are not defined as material defects. That is not to say that the home inspector will not report smaller defects such as cracked glass, broken outlets or leaky faucet washers but this is not the primary objective of an inspection. The home inspection is a first look attempt at ascertaining the general condition of a property. While it is the purpose of this inspection to discover and disclose those major items and concerns that may have an adverse impact on the value of this property and the health and safety of it's occupants, it is not an exhaustive list of defects or discrepancies and it certainly should not be used as a punch list of repairs. Repair list and cost estimates should be obtained from contractors. It is important to know that home inspectors are general practitioners with a limited amount of time and capabilities that is primarily focused on major issues in the home. Outside of normal testing and observation, Inspectors do not engage in troubleshooting or diagnostics and can not offer repair advice. home inspections are limited to visual observations only and does not include technically exhaustive or invasive analysis. However, this report attempts to identify and recommend conditions that should have further evaluation by experts prior to closing.
Typically included in any inspection report will be smaller issues, discrepancies, observations and suggestions. These may not be considered serious or significant problems but common to find on any home and is mostly provided as courtesy in an attempt to give you a more comprehensive understanding of the home.
It is the objective of the inspection and report to provide you the means by which you can progress in an informed manner thereby protecting yourself as much as possible before taking ownership of a property. This may mean obtaining further evaluation and repairs by an expert, purchase price adjustments, escrow of funds for repair, or withdrawing from a buyers purchase agreement altogether. If you are subject to an inspection contingency removal purchase addendum your conditions and disposition of removing that contingency should be clearly stated with details of expected outcomes. Furthermore, it should also be stated that any dispositions agreed to should be subjective to your re-inspection and final acceptance of satisfactory completion prior to closing of escrow.
Repairs - No matter how big or small, All repairs, corrections or replacements should be requested to be completed by licensed, qualified professionals with copies of their credentials, licensing, labor and product warranties and receipts of work. It is not recommend that you ask the seller to make the repairs unless they are qualified in the trades and you feel confident that they'll do a good quality job. It should be expected and required that all work be accompanied by any required city permits and inspections. Mostly all work except minor repairs require city permits and inspections. Finally, all repairs should be subject to your re-inspection, satisfaction and approval a couple days before closing.
Reinspection - Due to liability restrictions, reinspections are not the policy of Final Analysis home inspections. All repairs or corrections should be completed by qualified, licensed professional in their trade and should be accompanied by permits, work orders, receipts and warranties. If you feel a reinspection is necessary we can provide on a case by case basis and subject to schedule availability. The property inspection contingency removal addendum (PICRA) should be provided to us when the re-inspection is requested. All re-inspections are subject to a minimum fee of $200 and will be accompanied by an updated report.
NOTICE OF URGENCY: If you are buying this property, any discrepancies, concerns or issues revealed in this report should be resolved to your satisfaction before close of escrow and/or taking possession.
Overview: A thorough home inspection was completed at the subject property in accordance with the American Society Home Inspections (ASHI) standards. The inspection reveals that this dwelling has little wear and tear. Its structure and systems are generally sound, well built and maintained in good repair but with some typical discrepancies and deficiencies reported. All observations made and items reported here should be carefully reviewed and considered for correction where needed as they are specific to this home and can have a significant impact on it's condition, safety and value.
GENERAL ROOF CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Roof service life remaining::
80% - 100% (Very Good - No concerns) |
Roof covering material:
Architectural style asphalt shingles |
Viewed roof from:
Ground Attic |
Number of layers:
One |
Attic Ventilation:
Soffit intake vents installed 8x8 static roof outlet vents installed |
1.0 |
ROOF COVERINGS
Comments and observations: Inspected |
1.1 |
FLASHINGS
Comments and observations: Inspected |
1.2 |
SKYLIGHTS, CHIMNEYS and Other ROOF PENETRATIONS
Comments and observations: Inspected |
1.3 |
ROOF DRAINAGE SYSTEMS
Comments and observations: Inspected |
1.4 |
ATTIC VENTILATION
Comments and observations: Inspected |
General Statement - Attic ventilation plays an important role in reducing the heat loads in your attic, dissipating trapped moisture and contributing to the overall health of your attic/roof system. A poorly ventilated attic can reduce HVAC performance, shorten shingle life, and will promote rot of wood materials if moisture can't escape. Poor eave/soffit vents are the # reason for poor attic ventilation. Typically newer homes are better ventilated but older homes 20+ years, should be reviewed for improvement. It is important to remember that you need balanced intake vents along with outlet vents for good air flow. Installing just a power fan may not accomplish this. See more ventilation tips here Attic is ventilated |
GENERAL EXTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Siding material:
Vinyl |
Trim materials:
Aluminum coil stock Vinyl |
Exterior Entry Doors:
Steel |
Appurtenance:
Balcony Covered porch |
Driveway:
Concrete |
Evidence of water intrusion at exterior walls windows doors:
No |
2.0 |
Siding, Trim, Eaves, Flashings, Exterior finishes
Comments and observations: Inspected |
2.1 |
Doors (exterior)
Comments and observations: Inspected |
2.2 |
Windows (exterior)
Comments and observations: Inspected |
2.3 |
Decks, Balconies, Stoops, Steps, Porches, Patio/Sun rooms, Railings
Comments and observations: Inspected |
2.4 |
Vegetation, Grading, Drainage, Driveways, Walkways, Retaining walls (With respect to their effect on the condition of the building)
Comments and observations: Inspected |
General Information - Positive grading and drainage are essential to the welfare of a property, and are usually the primary concern of architects and builders. Moisture can deteriorate most surfaces, cause soil movement and erosion, and undermine the structures foundation. The ideal site will be graded to conduct water away from a building. In fact, the ideal building will be surrounded by hard surfaces that slope way from the exterior walls, the interior floors will be several inches higher than the exterior grade, and the building will have gutters and downspouts and a system of drainage designed to prevent any moisture from threatening the foundation or the living space. Unfortunately, many properties do not meet this ideal, conditions on most can generally be improved, and all need to be monitored and maintained to prevent damage. Also, inspectors cannot see inside area drains and do not water-test them, but they can become blocked by debris, occluded by silt, and damaged by movement. Therefore, buyers should question sellers about the functionality of any such system, have it serviced by a specialist, or assume the risk of having a system that does not function well and the damage that might result |
2.5 |
Garage, Garage door, opener safety reverse (if applicable)
Comments and observations: Inspected |
Defect, Safety - The garage overhead door is unbalanced (Item 1). The garage door should stay in place
at any location in it's travel. It should not fly open or drop shut. An unbalanced garage door can cause
personal injury and can cause stress damage to the door system. Recommend professional repairs be
completed by a qualified garage door technician.
2.5 (Item 1)
|
This inspection does not test for or report on the presence of MOLD or other indoor air quality issues or hazards.
GENERAL INTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Ceiling Materials:
Drywall, Sheet rock, Gypsum Plaster knock-down |
Wall Material:
Drywall, Sheetrock, Gypsum Plaster knock-down |
Floor Covering(s):
Carpet Hardwood T&G Tile |
Window Types:
Vinyl Tilt feature Single-hung Thermal/Insulated |
Interior Doors:
Hollow core Masonite Raised panel |
Cabinetry:
Wood |
Countertop:
Granite |
3.0 |
CEILINGS
Comments and observations: Inspected |
3.1 |
WALLS
Comments and observations: Inspected |
3.2 |
FLOORS
Comments and observations: Inspected |
3.3 |
STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments and observations: Inspected |
3.4 |
COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments and observations: Inspected |
3.5 |
DOORS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
3.6 |
WINDOWS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
GENERAL STRUCTURAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Is there significant structural faiulre/damage/distress was observed/suspected:
NO |
Crawl space access point:
N/A slab foundation |
Method used to observe Crawlspace:
No crawlspace |
Was there evidence of Termits- Powder post beetles or wood destroying fungus- mold- mildew- spores:
NO |
Was there evidence of Harmful Moisture / Water Conditions at foundation/crawlspace:
No |
Crawlspace ventilation:
N/A slab foundation |
Attic access:
Ceiling scuttle hole Light in attic |
Method used to observe attic:
Walked |
Was there evidence of Harmful Moisture Conditions in Attic:
No |
Foundation type:
Concrete slab |
Floor Structure:
Concrete slab on grade |
Wall Structure:
Conventional wood frame |
Columns or Piers:
N/A Concrete slab |
Ceiling Structure:
Enclosed, Concealed, Not visible |
Roof Structure:
Engineered wood trusses Sheathing Oriented strand board (OSB) |
Roof-Type:
Gable |
4.0 |
FOUNDATIONS, SLABS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. Fungus or wood destroying insects)
Comments and observations: Inspected |
4.1 |
STRUCTURAL FRAMING walls, floors, ceilings (where visible)
Comments and observations: Inspected |
No structural framing distress or failure was visibly detected. |
4.2 |
STRUCTURAL MASONRY, COLUMNS, PIERS, CONCRETE SLAB
Comments and observations: Inspected |
4.3 |
ROOF STRUCTURE AND ATTIC
Comments and observations: Inspected |
Disclosure: Buried, concealed or otherwise hidden piping including supply pipes and drain pipes that are not visible, are specifically excluded from this inspection. Questionable and suspect piping systems should be have an invasive, exhaustive evaluation completed by a plumbing contractor who may use video cameras, pressure testing and other means to determine the quality of pipes that are not possible during a visual home inspection.
GENERAL PLUMBING SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Probability of plumbing leaks:
Low |
Domestic Potable Water Source (not yard irrigation):
Public (municiple) |
Plumbing waste system:
City sewage |
Water Supply pipe (from street meter):
Not visible |
Water Distribution pipes (inside structure - visible areas only):
CPVC (hot and cold water use) |
Plumbing Waste / Drain pipe materials:
PVC (Polyvinyl Chloride) |
Domestic hot water source:
Electric storage tank |
Water Heater Capacity:
50 Gallon (2-3 people) |
Water heater service life remaining:
30% - 50% (Fair - No immediate cost concerns ouside of maintenance/repairs) |
Hot water temperature:
120-130 deg F. (typical) |
5.0 |
PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments and observations: Inspected |
5.1 |
PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments and observations: Inspected |
(1) Deficiency - The water heater overflow pan drain is draining into the washing machine drain which is
acceptable but the drain pipe is offset from the washing machine drain and may miss the drain pipe and
cause water damage (Item 1). Recommend professional repairs be completed by a qualified contractor.
5.1 (Item 1)
|
|
(2) Deficiency - Observed some minor glazing damage at the master bathroom jetted tub (Item 2).
Recommend professional repairs be completed by a qualified contractor.
5.1 (Item 2)
|
|
(3) Observation - The master bathroom jetted tub responds to testing at the time of the inspection .
5.1 (Item 3)
|
5.2 |
HOT WATER SYSTEMS
Comments and observations: Inspected |
General safety information about hot water temperatures - Hot water systems can be a scald
hazard and a source of disease. Water temperatures higher than 130 deg F. can be a scald hazard.
Water temperatures less than 120 deg. F. is considered ideal for the growth of harmful bacteria inside
the tank–such as Legionella (Item 1). Monitor your hot water temperatures for safety.
Information sources: http://EPA/Legionella: Drinking Water Health Advisory 5.2 (Item 1)
|
5.3 |
MAIN WATER SHUT-OFF DEVICE (Describe location)
Comments and observations: Inspected |
FYI - Primary water shut off is at municipal water meter. The secondary water shut off is in the garage
(Item 1).
5.3 (Item 1)
|
GENERAL ELECTRICAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Electrical inspection limitations:
None, Inspected in accordance with ASHI standards of practice. |
Electrical Service Cable (from utility pole or transformer):
Below ground Aluminum 4/0 cable |
Location of MAIN electric service panel(s):
garage |
Electric service and panel(s):
200 AMP Adequate capacity Remote main breaker Circuit breakers |
Branch circuit wiring/distribution for 15 and 20 AMP lighting and outlets:
Solid Copper Romex - NM plastic (normal - typical) Grounded (3 prong outlets) AFCI protection in bedrooms and smoke detector circuits |
Do smoke detectors respond to test?:
Yes |
6.0 |
SERVICE ENTRANCE CONDUCTORS
Comments and observations: Inspected |
6.1 |
SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments and observations: Inspected |
6.2 |
BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments and observations: Inspected |
6.3 |
CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments and observations: Inspected |
6.4 |
POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments and observations: Inspected |
6.5 |
OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
6.6 |
OPERATION OF AFCI (ARCH FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
Arch Fault Circuit Interrupts - This home was built with AFCI technology and therefore has AFCI protection in bedrooms. AFCI's protect against shorts, sparking and fires. AFCI's prevent fires. Click here for more information on AFCI's |
6.7 |
SMOKE DETECTORS
Comments and observations: Inspected |
6.8 |
CARBON MONOXIDE DETECTORS
Comments and observations: Not Present |
Safety - There is no carbon monoxide detector found in this home with an attached garage. It is recommended that one be installed according to the manufacturer's instructions. Read more about CO2 poisoning and safety at Consumer Products Safety Commission. |
Heat Type:
Heat Pump Forced Air (also provides cool air for AC) |
GENERAL AC/ HP SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
HEAT PUMP / AC - SERVICE LIFE REMAINING::
30% - 50% (Fair - No immediate cost concerns ouside of maintenance/repairs) |
Cooling Equipment Type:
Heat Pump Forced Air (also provides warm air, Heat) |
AC/Heat Pump system(s) performance:
Satisfactory |
AC/Heat Pump system(s) capacity:
Marginal / Undersized |
Number of Central AC / HP systems:
One |
Number of conditioned zones in the house/building:
3 |
Ductwork:
insulated flex duct Dual zone duct controls |
Filter Type:
Disposable clogged, replacement needed |
Types of Fireplaces:
None |
Number of operable fireplaces:
None |
Number of Woodstoves:
None |
7.0 |
AC COOLING, HEAT PUMP AND AIR HANDLER EQUIPMENT
Comments and observations: Inspected |
(1) Marginal capacity - The current Heat pump capacity of 2.5 tons appears to be marginal or undersized in relation to the reported square feet of conditioned space. An undersized system will still heat or cool with some effectiveness but may run continuously with reduced efficiency and shortened service life. Note: A "rule of thumb" is approximately 1 ton capacity needed per 580-600 square feet. A dwelling this size would typically require 3 tons. Note: Proper sizing varies widely and is a relatively technical determination made by an HVAC contractor using the Manual J load calculation formula. Because of the disparity noted here, It is recommended that you consider having this done. The cost of running undersized equipment can be more expensive that the replacement cost of properly sized equipment. | |
(2) Defect - Improper AC condensate drain and or trap configuration (Items 1 and 2). The drain should contain
a trap with a vent after the trap. Improper configuration will reduce efficiency and performance of the
system and can lead to clogged drain, back-ups and water damage. Recommend proper repairs be
completed by a qualified HVAC contractor using approved methods and materials. Urgency for repair is at
your discretion.
Note: Traps are designed to prevent external air from entering the AC system. Vents are designed to prevent a vacuum which can trap water in the pipe and lead to overflow. Vents should always be installed were the water leaves the trap. 7.0 (Item 1)
7.0 (Item 2)
|
|
(3) FYI - This home is heated and cooled with heat pump system(s). It is the same system and equipment
that provides warm air in the winter and cool air in the summer. When the outside temperature is below
60 deg. F. the system is tested in "heat" mode, When the outside temperature is above 60 deg.F. it is
tested in the "cool" mode. Heat pumps can only be tested in Heat or Cool but not both.
Most heat pump systems contain auxiliary (emergency, back-up) heat, typically electric coils but can be gas or oil. This is always tested winter or summer for response. However, some electronic thermostats when in "cool" mode will not allow manual switching to axillary heat, in which case it can not be tested. |
|
(4) Deficiency - Heat pump air handler overflow drain pipe is installed above the master bedroom balcony
door and may permit water intrusion into the door frame (Item 3). The drain pipe should be extended past
the door frame so it is visible if the drain overflows into the pan.
7.0 (Item 3)
|
|
(5) Equipment performance - The ambient air test was performed by using thermometers on the air handler
of Heat pump in cool mode to determine if the difference in temperatures of the supply and return air are
between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air
temperature on your system read 50 degrees (Item 4), and the return air temperature was 70 degrees
(Item 5). D/T = 20 Degrees F. This indicates satisfactory performance and the system is functioning as
designed..
7.0 (Item 4)
7.0 (Item 5)
|
|
(6) Observation - The heat pump electric back up heat responds to testing at the time of the inspection.
When tested in "emergency or auxiliary Heat" the output temperature reading is 94 Degrees F. and is
satisfactory (Item 6).
7.0 (Item 6)
|
7.1 |
PRESENCE OF INSTALLED AC/HP SOURCE AIR IN EACH ROOM
Comments and observations: Inspected |
7.2 |
NORMAL OPERATING CONTROLS
Comments and observations: Inspected |
7.3 |
DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments and observations: Inspected |
(1) Information - This homes HVAC system contains manual zone dampers at the supply plenum (Items 1
and 2). You can't see if the dampers are open or closed but you can tell by the position of the lever (Item
3). When the lever is parallel (in the same direction) as the duct, it is open, when the lever is
perpendicular (opposite direction of the duct) it is closed. 45 degrees would be half open. Zone dampers
are simply air valves inside the ductwork that allow you to control the air flow and comfort levels to
different zones in the home. For example, you may want to push more AC to the upstairs zone during the
summer season. In that case you would partially or fully close the damper that feeds the downstairs
ductwork and fully open the upstairs damper. In the summer time it would be the opposite. Remember no
matter what season it is, heat rises and cold air falls.
7.3 (Item 1)
7.3 (Item 2)
7.3 (Item 3)
|
|
(2) Maintenance - The disposable return filter is clogged and is dirty (Item 4). The filter needs to be replaced.
Note: a restricted return air filter can cause reduced air flow, reduced efficiency and damage to equipment.
7.3 (Item 4)
|
GENERAL INSULATION CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Attic insulation:
Loose or blown in fiberglass Approx. R38, meets DOE current standards good |
Wall insulation:
concealed, not visible, not inspected |
Floor System Insulation:
N/A slab construction |
Bathroom steam vents:
Fan Window |
Dryer Power Source:
220 Electric NOTE: This dryer outlet requires a 3 prong plug |
Dryer duct (built in):
Metal Dryer duct flow not tested. Dryer not in place |
8.0 |
INSULATION IN ATTIC / CEILING
Comments and observations: Inspected |
8.1 |
Wall insulation (if visible)
Comments and observations: Not Inspected |
8.2 |
INSULATION UNDER FLOOR SYSTEM
Comments and observations: Not Present |
8.3 |
VENTING SYSTEMS (Kitchens, baths and laundry)
Comments and observations: Inspected |
SAFETY ADVISORY- Dryer ducts should be cleaned and inspected annually for proper performance.
Dryer ducts are susceptible to clogging and blockage due to lint and moisture build up. Restricted
dryer vents will not only reduce drying efficiency, but worse they can overheat and cause fires.
If your dryer used a vinyl or foil flex duct connector you should dispose of it and replace with flexible aluminum duct. Aluminum duct is the most efficient type, safest type to reduce fire hazards and the only type recommended by dryer manufactures and by most municipal building codes. Dryer vent installation guidelines See more about dryer duct safety here. |
GENERAL APPLIANCE CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
GARBAGE DISPOSAL:
Functional |
DISHWASHER:
Functional |
RANGE/OVEN/STOVE/COOK TOP:
Functional |
MICROWAVE OVEN (built in):
Functional |
STOVE EXHAUST / RANGE HOOD:
Functional Not vented to exterior. Recirculate type. |
INDOOR DOWN DRAFT GRILL:
None installed |
TRASH COMPACTOR:
None installed |
9.0 |
DISHWASHER
Comments and observations: Inspected |
9.1 |
RANGES/OVENS/COOKTOPS
Comments and observations: Inspected |
9.2 |
RANGE HOOD
Comments and observations: Inspected |
9.3 |
TRASH COMPACTOR
Comments and observations: Not Present |
9.4 |
GARBAGE DISPOSAL UNIT
Comments and observations: Inspected |
9.5 |
MICROWAVE COOKING EQUIPMENT
Comments and observations: Inspected |