Property Inspection Report
|
||||||||
Final Analysis Home Inspections 5020 Ferrell Pkwy. Virginia Beach VA 23464 |
||||||||
Prepared exclusively for removed for privacy |
||||||||
xxxx Sanderlin Ln Virginia Beach VA 23464 |
||||||||
|
||||||||
|
||||||||
Report ID:
071315 |
||||||||
Inspection Date:
7/13/2015 |
||||||||
Inspected By: Adam Comeau
|
||||||||
757.495.2300 |
||||||||
Date: 7/13/2015 | Time: 01:00 PM | Report ID: Basnet071315 |
Property: Sanderlin Ln Virginia Beach VA 23464 |
Customer: removed for privacy |
Real Estate Professional: |
Type of Inspection: Home Buyers inspection | Inspection Procedures: American Society of Home Inspectors, Standards of practice | Inspection Restrictions/limitations: None |
General inspection accessibility: Occupied, furnished | All Utility services are on?: Yes | In Attendance: Buyer, Buyers Agent |
Type of building: Single Family (2 story) | Square Feet of conditioned space: 1,566 | Age of building (year built): 1979 |
# of Bedrooms: 3 Bedrooms | # of Bathrooms: 2.5 bathrooms | Temperature during inspection: 80 |
Weather: Cloudy | Ground/Soil surface condition: Dry | Garage: Attached, 1 car |
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it is satisfactory and appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit does not exists in this home or building.
Information & Disclosures (ID) = Important information you should know about this house or building including, disclosures, alerts, advisories and warnings about typical conditions or circumstances for this home. Not necessarily something abnormal or unusual but critical information that may pose significant concern for health risk, environmental safety or additional cost. These items will be indicated with an Orange Flag
Repair or Replace (RR) = The item, component or unit is not functioning as intended, defective, broken or otherwise needs further inspection and evaluation by a qualified contractor. Items, components or units that should be repaired, replaced or corrected. These will be indicated with a Red Flag
Inspection standards: This inspection was completed in compliance with the professional standards of practice set forth by the American Society of Home inspectors (ASHI)
Purpose and Objective: This inspection is not technically exhaustive and can not be conclusive of every detail. The primary objective of this building inspection is to identify and report MATERIAL DEFECTS. Material Defects are defined as a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material defect. Normal wear and tear, maintenance typical defects or deficiencies are not defined as material defects. That is not to say that the home inspector will not report smaller defects such as cracked glass, broken outlets or leaky faucet washers but this is not the primary objective of an inspection. The home inspection is a first look attempt at ascertaining the general condition of a property. While it is the purpose of this inspection to discover and disclose those major items and concerns that may have an adverse impact on the value of this property and the health and safety of it's occupants, it is not an exhaustive list of defects or discrepancies and it certainly should not be used as a punch list of repairs. Repair list and cost estimates should be obtained from contractors. It is important to know that home inspectors are general practitioners with a limited amount of time and capabilities that is primarily focused on major issues in the home. Outside of normal testing and observation, Inspectors do not engage in troubleshooting or diagnostics and can not offer repair advice. home inspections are limited to visual observations only and does not include technically exhaustive or invasive analysis. However, this report attempts to identify and recommend conditions that should have further evaluation by experts prior to closing.
Typically included in any inspection report will be smaller issues, discrepancies, observations and suggestions. These may not be considered serious or significant problems but common to find on any home and is mostly provided as courtesy in an attempt to give you a more comprehensive understanding of the home.
It is the objective of the inspection and report to provide you the means by which you can progress in an informed manner thereby protecting yourself as much as possible before taking ownership of a property. This may mean obtaining further evaluation and repairs by an expert, purchase price adjustments, escrow of funds for repair, or withdrawing from a buyers purchase agreement altogether. If you are subject to an inspection contingency removal purchase addendum your conditions and disposition of removing that contingency should be clearly stated with details of expected outcomes. Furthermore, it should also be stated that any dispositions agreed to should be subjective to your re-inspection and final acceptance of satisfactory completion prior to closing of escrow.
Repairs - No matter how big or small, All repairs, corrections or replacements should be requested to be completed by licensed, qualified professionals with copies of their credentials, licensing, labor and product warranties and receipts of work. It is not recommend that you ask the seller to make the repairs unless they are qualified in the trades and you feel confident that they'll do a good quality job. It should be expected and required that all work be accompanied by any required city permits and inspections. Mostly all work except minor repairs require city permits and inspections. Finally, all repairs should be subject to your re-inspection, satisfaction and approval a couple days before closing.
Reinspection - Due to liability restrictions, reinspections are not the policy of Final Analysis home inspections. All repairs or corrections should be completed by qualified, licensed professional in their trade and should be accompanied by permits, work orders, receipts and warranties. If you feel a reinspection is necessary we can provide on a case by case basis and subject to schedule availability. The property inspection contingency removal addendum (PICRA) should be provided to us when the re-inspection is requested. All re-inspections are subject to a minimum fee of $200 and will be accompanied by an updated report.
NOTICE OF URGENCY: If you are buying this property, any discrepancies, concerns or issues revealed in this report should be resolved to your satisfaction before close of escrow and/or taking possession.
NOTICE - A Termite and moisture inspection was not ordered or completed during this inspection by Final Analysis Property inspections LLC. These are the specific inspections and reports required by some financial institutions to underwrite a mortgage. Termite and Moisture inspections look for and report on the presence of wood damaging organisms. These inspections are typically performed by home inspections company's or pest control companies. It is strongly recommended that you have this completed or have the seller provide termite and moisture clearance documents from a qualified company before taking ownership of the property. Additionally you should have annual inspections for the presence of wood damaging organisms.
Overview: A thorough home inspection was completed at the subject property in accordance with the American Society Home Inspections (ASHI) standards. The inspection reveals that this dwelling has normal wear and tear. Its structure and systems are generally sound and well built but with multiple aging systems, workmanship defects at siding and other discrepancies and deficiencies reported. All observations made and items reported here should be carefully reviewed and considered for correction where needed as they are specific to this home and can have a significant impact on it's condition, safety and value.
Significant concerns (highlights)- The following systems, components or items may represent significant concerns regarding cost, safety or value:
HVAC (Aging, expired life), Exterior (Amateur siding and trim installation)
See report sections for details.
GENERAL ROOF CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Roof service life remaining::
30% - 50% (Fair - No immediate cost concerns ouside of maintenance/repairs) |
Roof covering material:
3-Tab fiberglass |
Viewed roof from:
Walked roof Attic |
Number of layers:
One |
Attic Ventilation:
Ridge vents Soffit intake vents installed |
1.0 |
ROOF COVERINGS
Comments and observations: Inspected |
Observation - The roof shingle covering is currently in satisfactory condition but is showing signs of age. Some of the current conditions noted are surface wear, granular erosion and outdated, deteriorated ridge cap shingles. Though the roof does not need immediate replacement, the cost of replacing should be considered and budgeted for in the next 5 to 7 years. In the meantime, maintenance such as flashings, repair of broken shingles, leaky pipe and vent penetrations will increase as the roof continues to age. |
1.1 |
FLASHINGS
Comments and observations: Inspected |
1.2 |
SKYLIGHTS, CHIMNEYS and Other ROOF PENETRATIONS
Comments and observations: Inspected |
1.3 |
ROOF DRAINAGE SYSTEMS
Comments and observations: Inspected |
(1) Deficiency - The gutters are full of debris in areas, not draining as designed and need to be cleaned at the garage roof (Items 1 and 2). The debris
in gutters can also conceal rust, deterioration or leaks that are not visible until cleaned. Recommend professional cleaning, inspection and any
repair maintenance needed to restore function as intended.
1.3 Picture 1
1.3 Picture 2
|
|
(2) Defect - Gutters have suffered delayed maintenance and are in general disrepair. They are not draining as designed. Observed sagging at the left
side (as viewed from the front of the house) and is further evidenced by overflow grade washout below (Item 3). Poorly functioning gutters can cause
rot damage to the trim and cause erosion and water intrusion at the foundation. Recommend repair and replace gutters as needed to restore
adequate roof drainage.
1.3 Picture 3
|
1.4 |
ATTIC VENTILATION
Comments and observations: Inspected |
(1) Defect - Aging, worn and deteriorating aluminum ridge vents still in use. The ridge vents should have been replaced when the roof shingle covering
was replaced. The ridge vents are lifting (Items 1 and 2) and the ridge cap shingles beneath the vents are detaching and falling (Items 3 and 4).
Recommend professional repairs be completed by a qualified roofing contractor using approved methods and materials.
1.4 Picture 1
1.4 Picture 2
1.4 Picture 3
1.4 Picture 4
|
|
(2) General Statement - Attic ventilation plays an important role in reducing the heat loads in your attic, dissipating trapped moisture and contributing
to the overall health of your attic/roof system. A poorly ventilated attic can reduce HVAC performance, shorten shingle life, and will promote rot of
wood materials if moisture can't escape. Poor eave/soffit vents are the # reason for poor attic ventilation. Typically newer homes are better
ventilated but older homes 20+ years, should be reviewed for improvement. It is important to remember that you need balanced intake vents along
with outlet vents for good air flow. Installing just a power fan may not accomplish this. See more ventilation tips here
Attic is ventilated |
GENERAL EXTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Siding material:
Vinyl |
Trim materials:
Aluminum coil stock Vinyl |
Exterior Entry Doors:
Steel |
Appurtenance:
Sidewalk Patio |
Driveway:
Concrete |
Evidence of water intrusion at exterior walls windows doors:
No |
2.0 |
Siding, Trim, Eaves, Flashings, Exterior finishes
Comments and observations: Inspected |
(1) Defect - The vinyl siding on the right side of the fireplace chimney flue is loose, detached and fallen and is subject to water intrusion (Item 1).
Recommend professional repairs be completed by a qualified contractor using approved methods and materials.
2.0 Picture 1
|
|
(2) Defect - Observed several areas of physically damaged vinyl siding around the entire exterior lower siding panels (Items 2-9) and inadequate repairs
to vinyl siding at the fireplace where a siding panel has been improperly nailed over a damaged section of siding (Item 10). Recommend cost
estimates and professional repairs be completed by a qualified contractor using approved methods and materials.
2.0 Picture 2
2.0 Picture 3
2.0 Picture 4
2.0 Picture 5
2.0 Picture 6
2.0 Picture 7
2.0 Picture 8
2.0 Picture 9
2.0 Picture 10
|
|
(3) Defect - Amateur, substandard workmanship observed at all vinyl siding and metal trim cladding in general. Workmanship does not meet basic
industry quality standards and is subject to fail. Observed improperly overlapped siding, Missing finish trim at top panels. The metal trim is not
installed or sealed in a way to prevent water shed or damaging intrusion (Items 11 and 12). Caulk materials are improper silicon and not sticking to
the vinyl at trim pieces and windows (Items 13 and 14). Drip caps are missing from door and window headers. Poorly installed vinyl siding and trim
are subject to detachment and damaging wind/water intrusion. Cost of correction may be significant. Recommend further evaluation and cost
estimates and repairs/replacement be obtained/completed by a qualified siding/trim contractor using approved methods and materials.
2.0 Picture 11
2.0 Picture 12
2.0 Picture 13
2.0 Picture 14
|
2.1 |
Doors (exterior)
Comments and observations: Inspected |
Workmanship Defect - The garage overhead door and the replacement rear sliding patio door is not properly flashed with drip cap flashing at
header trim (Item 1). Drip cap flashing provides water shed away from the door opening at the top (Item 2). Caulk is not acceptable. In fact caulk
can trap water in. The affected areas are subject to water intrusion and damage to the wall structure. Correction is recommended as a preventative
measure. At a minimum these areas should be monitored for water stains and wetness before any serious damage occurs.
2.1 Picture 1 Garage overhead door
2.1 Picture 2
|
2.2 |
Windows (exterior)
Comments and observations: Inspected |
Workmanship Defect - Replacement windows are not properly flashed with drip cap flashing at header trim (Item 1 and 2). Drip cap flashing
provides water shed away from the window opening at the top (Item 3). Caulk is not acceptable. In fact caulk can trap water in. The affected areas
are subject to water intrusion and damage to the wall structure. Correction is recommended as a preventative measure. At a minimum these areas
should be monitored for water stains and wetness before any serious damage occurs.
2.2 Picture 1
2.2 Picture 2
2.2 Picture 3
|
2.3 |
Decks, Balconies, Stoops, Steps, Porches, Patio/Sun rooms, Railings
Comments and observations: Inspected |
Defect - The front porch roof overhang post is inadequately fastened at the top and base, is loose and subject to detachment (Items 1 and 2).
Recommend professional repairs be completed by a qualified contractor using approved methods and materials.
2.3 Picture 1
2.3 Picture 2
|
2.4 |
Vegetation, Grading, Drainage, Driveways, Walkways, Retaining walls (With respect to their effect on the condition of the building)
Comments and observations: Inspected |
(1) General Information - Positive grading and drainage are essential to the welfare of a property, and are usually the primary concern of architects and builders. Moisture can deteriorate most surfaces, cause soil movement and erosion, and undermine the structures foundation. The ideal site will be graded to conduct water away from a building. In fact, the ideal building will be surrounded by hard surfaces that slope way from the exterior walls, the interior floors will be several inches higher than the exterior grade, and the building will have gutters and downspouts and a system of drainage designed to prevent any moisture from threatening the foundation or the living space. Unfortunately, many properties do not meet this ideal, conditions on most can generally be improved, and all need to be monitored and maintained to prevent damage. Also, inspectors cannot see inside area drains and do not water-test them, but they can become blocked by debris, occluded by silt, and damaged by movement. Therefore, buyers should question sellers about the functionality of any such system, have it serviced by a specialist, or assume the risk of having a system that does not function well and the damage that might result | |
(2) Deficiency - The left side (as viewed from front of house) lot is level, has grade depressions or is otherwise poorly graded in a way that is not
conducive to good water shed and positive drainage (Item 1). generally speaking, the lot should be crowned around the dwelling and have a positive
slope that drains water away from structure and to edges of property and eventually into the storm drains. Lots with poor drainage can cause a wide
range of problems with the structure if the water is pooling around the foundation or entering the crawlspace. Additionally poor drainage or standing
water may cause a muddy lot and fungal growth on the yard. It is recommended that this condition be considered for improvement.
2.4 Picture 1
|
2.5 |
Garage, Garage door, opener safety reverse (if applicable)
Comments and observations: Inspected |
(1) Defect, Safety - The garage overhead door is unbalanced (Item 1). The garage door should stay in place at any location in it's travel. It should not
fly open or drop shut. An unbalanced garage door can cause personal injury and can cause stress damage to the door system. Recommend
professional repairs be completed by a qualified garage door technician.
2.5 Picture 1
|
|
(2) Defect - The bottom seal and both side seals are physically damaged at the garage door which may permit water and air intrusion (Items 2-4). The
bottom seal also protects the bottom of the garage door by isolating it from the moist concrete surface which can cause rust or rot damage.
Recommend professional repairs be completed by a qualified contractor.
2.5 Picture 2
2.5 Picture 3
2.5 Picture 4
|
|
(3) Inspection Restriction - The garage is heavily congested with personal property at the time of the inspection (Items 5 and 6). The garage
inspection was limited to visible areas only.
2.5 Picture 5
2.5 Picture 6
|
This inspection does not test for or report on the presence of MOLD or other indoor air quality issues or hazards.
GENERAL INTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Ceiling Materials:
Drywall, Sheet rock, Gypsum Plaster veneer |
Wall Material:
Drywall, Sheetrock, Gypsum Plaster |
Floor Covering(s):
Carpet Laminated T&G |
Window Types:
Vinyl Tilt feature Thermal/Insulated Sliders |
Interior Doors:
Hollow core Masonite Raised panel |
Cabinetry:
Wood |
Countertop:
Laminate |
3.0 |
CEILINGS
Comments and observations: Inspected |
3.1 |
WALLS
Comments and observations: Inspected |
3.2 |
FLOORS
Comments and observations: Inspected |
3.3 |
STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments and observations: Inspected |
(1) Safety - Pickets at railings are spaced greater than 4" apart (Item 1). This is safety hazard for small children and no longer permitted in new
construction. Recommend using precautions with small children such as safety barrier or netting.
3.3 Picture 1
|
|
(2) SAFETY - Handrails missing at the bottom of the interior steps (Item 2). In older homes this was not required but has been required for many years
in newer construction. This information is provided for your safety.
3.3 Picture 2
|
|
(3) Safety - Handrails at the interior steps are not graspable (Item 4). Handrails shape must such that they are "graspable". The hand grip portion of
the handrail must not be less than 1 ¼ inches or more than 2 inches in a circular cross-sectional dimension. If other than circular, the configuration
must be such that it provides an equivalent, "graspable" shape. Where the cross section of the handrail is not circular, an alternate shape that
provides a perimeter dimension of at least 4 inches and not greater than 6.25 inches with a maximum cross-section dimension of 2.25 inches is
required. See examples
3.3 Picture 3
3.3 Picture 4
|
3.4 |
COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments and observations: Inspected |
3.5 |
DOORS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
(1) Deficiency - The sliding closet doors are missing in the front left bedroom (Item 1) and the left rear bedroom (Item 2). Recommend replacement be
completed as needed by a qualified contractor.
3.5 Picture 1
3.5 Picture 2
|
|
(2) Deficiency - The powder room door and laundry room door have fallen out of square and are binding on the door frame (Items 3 and 4).
Recommend professional repairs be completed by a qualified contractor.
3.5 Picture 3 Powder room
3.5 Picture 4 Laundry room
|
3.6 |
WINDOWS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
(1) Defect - Insulated glass (IG unit) seal failure - The glazing seal has failed causing etching, fogged appearance and condensation between the
glass panes in the master bedroom right side sliding window (Item 1) and at the kitchen dining area window right side sliding window (Item 2). The
insulated double pane glazing has compromised thermal properties in addition to permanent cosmetic damage. The typical repair is to
replace the thermal glass (IG unit) with new. There are several local service providers / contractors that specialize in this type of repair. It is
recommended you contact them for further evaluation and to obtain repair cost estimates.
Be Advised: Evidence of seal failure is affected by environmental temperature and humidity levels making it difficult to detect and not always visible during the inspection but may surface later. Recommend additional inspections before close of escrow be completed during your walk through inspection. Additionally, if multiple windows in the home have seal failure it should be expected that other windows are likely to fail in the future do to age and poor factory design. 3.6 Picture 1
3.6 Picture 2
|
|
(2) FYI - The vinyl replacement windows are dated 2009 (Item 3).
3.6 Picture 3
|
GENERAL STRUCTURAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Is there significant structural faiulre/damage/distress was observed/suspected:
NO |
Crawl space access point:
N/A slab foundation |
Method used to observe Crawlspace:
No crawlspace |
Was there evidence of Termits- Powder post beetles or wood destroying fungus- mold- mildew- spores:
NO |
Was there evidence of Harmful Moisture / Water Conditions at foundation/crawlspace:
No |
Crawlspace ventilation:
N/A slab foundation |
Attic access:
Ceiling scuttle hole |
Method used to observe attic:
Walked |
Was there evidence of Harmful Moisture Conditions in Attic:
No |
Foundation type:
Concrete slab |
Floor Structure:
Concrete slab on grade |
Wall Structure:
Conventional wood frame |
Columns or Piers:
N/A Concrete slab |
Ceiling Structure:
Conventional wood frame |
Roof Structure:
Engineered wood trusses Plywood Sheathing |
Roof-Type:
Shed |
4.0 |
FOUNDATIONS, SLABS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. Fungus or wood destroying insects)
Comments and observations: Inspected |
Slab / Foundation block is even or below grade level and vulnerable to moisture intrusion and rot damage to wall framing along sill plate at left
side (As viewed from the front of the house) (Item 1). These areas should be cleared away and inspected for damage. Improvements such as proper
grading, drainage and foundation water proofing is also recommended to be completed by a qualified person or contractor experienced in correcting
these conditions.
4.0 Picture 1
|
4.1 |
STRUCTURAL FRAMING walls, floors, ceilings (where visible)
Comments and observations: Inspected |
No structural framing distress or failure was visibly detected. |
4.2 |
STRUCTURAL MASONRY, COLUMNS, PIERS, CONCRETE SLAB
Comments and observations: Inspected |
4.3 |
ROOF STRUCTURE AND ATTIC
Comments and observations: Inspected |
Disclosure: Buried, concealed or otherwise hidden piping including supply pipes and drain pipes that are not visible, are specifically excluded from this inspection. Questionable and suspect piping systems should be have an invasive, exhaustive evaluation completed by a plumbing contractor who may use video cameras, pressure testing and other means to determine the quality of pipes that are not possible during a visual home inspection.
GENERAL PLUMBING SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Probability of plumbing leaks:
Low |
Domestic Potable Water Source (not yard irrigation):
Public (municiple) |
Plumbing waste system:
City sewage |
Water Supply pipe (from street meter):
Not visible |
Water Distribution pipes (inside structure - visible areas only):
Copper |
Plumbing Waste / Drain pipe materials:
PVC (Polyvinyl Chloride) |
Domestic hot water source:
Electric storage tank |
Water Heater Capacity:
40 Gallon (1-2 people) |
Water heater service life remaining:
50% - 80% (Good - No concerns outside of normal maintenance) |
Hot water temperature:
120-130 deg F. (typical) |
Main water shut off location:
At the street municipal meter location |
5.0 |
PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments and observations: Inspected |
5.1 |
PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments and observations: Inspected |
(1) Defect - Toilet is loose at floor mounts and drain flange in the downstairs half bath and is subject to leaking at base. Repairs may involve re-setting
the toilet on a new wax seal. Water can leak into the flooring and cause damage that is not detectable at first. Recommend a qualified licensed
plumber repair or correct as needed.
5.1 Picture 1
|
|
(2) Deficiency - The washing machine supply hoses are an older style rubber hose that is subject to split and burst (Item 3). Recommend
replacement with higher quality braided steel supply hoses be completed as needed.
5.1 Picture 2
5.1 Picture 3
|
|
(3) Defect - Toilet is loose at floor mounts and drain flange in master bath and is subject to leaking at base (Item 4). Repairs may involve re-setting the
toilet on a new wax seal. Water can leak into the flooring and cause damage that is not detectable at first. Recommend a qualified licensed
plumber repair or correct as needed.
5.1 Picture 4
|
|
(4) Defect - Sink is loose or not properly fastened to wall or base cabinet in downstairs half bath (Item 5). Fixtures that have water pipes or drain pipes
must be physically fastened to prevent movement and possible breakage or separation of pipes. This may include fastening both the sink and the
cabinet to each other and the wall. It is recommend that this be corrected by a qualified tradesman.
5.1 Picture 5
|
|
(5) 6Defect - Amateur workmanship or improper materials. Observed the use off flex connectors at the master bathroom (Item 6) and upstairs hall bath
(Item 7). These flex connectors are intended for temporary use. This drain is subject to clogs, poor drainage and failure. All drainage fittings shall
have a smooth interior waterway of the same diameter as the piping served. Recommend further evaluation and repairs be completed by a qualified
plumbing contractor using approved methods and materials.
5.1 Picture 6
5.1 Picture 7
|
|
(6) Defect - Backflow preventer device is missing from the front (Item 8) and rear (Item 9) hose bibs where amateur yard irrigation piping has been
installed. Backflow preventers are required to prevent bacterial cross connect and contamination of municipal water supplies (Item 10). Recommend
professional corrections be completed by a qualified plumbing contractor.
5.1 Picture 8
5.1 Picture 9
5.1 Picture 10
|
5.2 |
HOT WATER SYSTEMS
Comments and observations: Inspected |
(1) General safety information about hot water temperatures - Hot water systems can be a scald hazard and a source of disease. Water
temperatures higher than 130 deg F. can be a scald hazard. Water temperatures less than 120 deg. F. is considered ideal for the growth of harmful
bacteria inside the tank–such as Legionella (Item 1). Monitor your hot water temperatures for safety.
Information sources: http://EPA/Legionella: Drinking Water Health Advisory 5.2 Picture 1
|
|
(2) Deficiency - The installed water heater capacity (40 Gallon) and recovery rating appears undersized for the potential hot water demand required of
the installed fixtures and equipment (Item 2). This should be re-evaluated when it comes time for replacement. Replacement cost can vary widely
and can be significant. read more about water heater here.
5.2 Picture 2
|
5.3 |
MAIN WATER SHUT-OFF DEVICE (Describe location)
Comments and observations: Inspected |
FYI - Primary water shut off is at municipal water meter. |
GENERAL ELECTRICAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Electrical inspection limitations:
None, Inspected in accordance with ASHI standards of practice. |
Electrical Service Cable (from utility pole or transformer):
Below ground Aluminum 2/0 cable |
Location of MAIN electric service panel(s):
garage |
Electric service and panel(s):
150 AMP Adequate capacity Circuit breakers Split buss (old style, no main disconnect, typical for age) |
Branch circuit wiring/distribution for 15 and 20 AMP lighting and outlets:
Solid Copper Romex - NM plastic (normal - typical) Grounded (3 prong outlets) |
Do smoke detectors respond to test?:
Recommend updating for safety |
6.0 |
SERVICE ENTRANCE CONDUCTORS
Comments and observations: Inspected |
6.1 |
SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments and observations: Inspected |
6.2 |
BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments and observations: Inspected |
6.3 |
CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments and observations: Inspected |
(1) Defect, Safety - The garbage disposal conduit is detached from the junction box, romex wires are exposed and is a shock and electrocution
hazard (Item 1). Recommend professional repairs be completed by a qualified electrical contractor.
6.3 Picture 1
|
|
(2) Defect - Amateur light switch installation observed in the kitchen (Items 2 and 3) and the stairwell (Items 4 and 5). The kitchen and dining room
have a 2 way switch installed on a 3 way circuit which means that when the light switch is in the off position, the 2nd switch will not respond and
vice versa. Recommend professional repairs be completed by a qualified electrical contractor.
6.3 Picture 2
6.3 Picture 3
6.3 Picture 4
6.3 Picture 5
|
6.4 |
POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments and observations: Inspected |
(1) Defect, Safety - Reversed wiring was detected at the laundry area outlet (Item 1). Reversed wiring refers to a condition where the "Hot and Neutral"
(black and white) wires are reversed on the outlet terminals or somewhere else in the circuit (Item 2). While the outlet will still function normally it
presents a shock / electrocution hazard under certain conditions (Item 3). This is also evidence that the home's wiring was worked on by someone
who was not qualified. This is a relatively simple and inexpensive condition to correct but should be done by a qualified electrician.
6.4 Picture 1
6.4 Picture 2
6.4 Picture 3
|
|
(2) Defect, Safety - An "open ground" reading was detected at all outlets in the front left bedroom (Items 4-6), left rear bedroom left interior wall outlet
(Item 7) and the master bedroom rear exterior wall outlet (Item 8). Open grounds are caused by an opening in the ground circuit somewhere
between the affected outlet and the main electric service panel (Item 9). Typically it's a loose wire on the outlets ground terminal, but it can be
anywhere in the circuit such as an upstream outlet that feeds this outlet. The ground circuit is designed to divert dangerous electricity away from
your body and prevent electrocution. Ungrounded outlets are unsafe and can cause injury or death. It is recommended that this condition be further
evaluated and corrected by a qualified electrician.
6.4 Picture 4
6.4 Picture 5
6.4 Picture 6
6.4 Picture 7
6.4 Picture 8
6.4 Picture 9
|
6.5 |
OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
Defect, Safety - GFCI outlets are missing in the kitchen (Item 1), the upstairs hall bathroom (Item 2) and master bathroom (Item 3) and is a shock
and electrocution hazard. Recommend professional repairs be completed by a qualified electrical contractor. GFCI's save lives!
6.5 Picture 1
6.5 Picture 2
6.5 Picture 3
|
6.6 |
OPERATION OF AFCI (ARCH FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Not Present |
Information/Disclosure - Non Arch Fault Circuit Interrupts , SAFETY - This home was built before AFCI technology and therefore is missing
some or all AFCI protection in bedrooms. AFCI's protect against shorts, sparking and fires.. Recommend consider upgrading to AFCI
protection.
“Older homes are statistically more vulnerable to electrical fires. Extra protection for older homes is provided by the gradual replacement, over time, of non-AFCI-protected receptacles with new AFCI-protected ones.” The NEC AFCI's prevent fires. Click here for more information on AFCI's |
6.7 |
SMOKE DETECTORS
Comments and observations: Inspected |
(1) Safety - One or more installed smoke detectors are outdated, unreliable (Item 1). Have repaired or replaced as needed by a professional. Test
again during final walk-thru inspection then continue to test monthly. Properly working smoke detectors save lives.
6.7 Picture 1
|
|
(2) Safety - Install modern smoke detectors where needed for safety and test monthly. Read more about smoke detectors at US consumer safety
products commission. and at National Fire Protection Association.
The two most commonly recognized smoke detection technologies are ionization smoke detection and photoelectric smoke detection. Ionization smoke detection is generally more responsive to flaming fires. How they work: Ionization-type smoke alarms have a small amount of radioactive material between two electrically charged plates, which ionizes the air and causes current to flow between the plates. When smoke enters the chamber, it disrupts the flow of ions, thus reducing the flow of current and activating the alarm. Photoelectric smoke detection is generally more responsive to fires that begin with a long period of smoldering (called “smoldering fires”). |
6.8 |
CARBON MONOXIDE DETECTORS
Comments and observations: Not Present |
Safety - There is no carbon monoxide detector found in this home with an attached garage and a wood burning fireplace. It is recommended that one be installed according to the manufacturer's instructions. Read more about CO2 poisoning and safety at Consumer Products Safety Commission. |
Heat Type:
Heat Pump Forced Air (also provides cool air for AC) |
GENERAL AC/ HP SYSTEM CONDITION / RATING:
Poor (Not functioning as designed, worn out, safety concerns, additional expense.) |
HEAT PUMP / AC - SERVICE LIFE REMAINING::
20% or less (plan for replacement, consider cost) |
Cooling Equipment Type:
Heat Pump Forced Air (also provides warm air, Heat) |
AC/Heat Pump system(s) performance:
Unsatisfactory |
AC/Heat Pump system(s) capacity:
Marginal / Undersized |
Number of Central AC / HP systems:
One |
Number of conditioned zones in the house/building:
2 |
Ductwork:
Enclosed, built in, concealed Metal |
Filter Type:
Disposable clogged, replacement needed |
Types of Fireplaces:
Factory pre-fab metal Wood burning |
Number of operable fireplaces:
One |
Number of Woodstoves:
None |
7.0 |
AC COOLING, HEAT PUMP AND AIR HANDLER EQUIPMENT
Comments and observations: Inspected |
(1) Aging Heat Pump Equipment - The Heat Pump system is aging and has reached its service life expectancy (Mfg. 1999, Old). Replacement in the near future is inevitable and should be planned and budgeted for. At a minimum you may consider having it cleaned, served and tested by a qualified HVAC contractor in addition to further protection by obtaining a whole house warranty during purchase. | |
(2) Marginal Heat Pump Capacity - The current Heat pump capacity of 2 tons appears to be marginal or undersized in relation to the reported square feet of conditioned space. An undersized system will still heat or cool with some effectiveness but may run continuously with reduced efficiency and shortened service life. Note: A "rule of thumb" is approximately 1 ton capacity needed per 580-600 square feet. A dwelling this size would typically require 2.5 tons. Note: Proper sizing varies widely and is a relatively technical determination made by an HVAC contractor using the Manual J load calculation formula. Because of the disparity noted here, It is recommended that you consider having this done. The cost of running undersized equipment can be more expensive that the replacement cost of properly sized equipment. | |
(3) Defect - Improper A/C condensate drain and or trap configuration (Items 1 and 2). The drain should contain a trap with a vent after the trap.
Improper configuration will reduce efficiency and performance of the system and can lead to clogged drain, back-ups and water damage.
Recommend proper repairs be completed by a qualified HVAC contractor using approved methods and materials. Urgency for repair is at your
discretion.
Note: Traps are designed to prevent external air from entering the AC system. Vents are designed to prevent a vacuum which can trap water in the pipe and lead to overflow. Vents should always be installed were the water leaves the trap. 7.0 Picture 1
7.0 Picture 2
|
|
(4) Disclosure - Older design - This Heat Pump system is designed for use with R22 refrigerant AKA "Freon®" which is now considered obsolete.
R22 has been replaced with R410a refrigerant; AKA "Puron®". As a homeowner or home buyer considering a purchase, it’s important that you
understand the difference so you can make the best decision for your system while considering your purchase.
R-22 - Often referred to by a brand name like Freon® - As of 2010, R-22 was outlawed for use in new air conditioning systems - R-22 is a hydro-chlorofluorocarbon (HCFC) which contributes to ozone depletion - Is very expensive (cost prohibitive) and will increase as limited supplies are depleted. - R424A is an R22 alternative that can be used in older R22 systems that is ozone friendly but it is almost as expensive as R22 and not as efficient. R-410A - Often referred to by a brand name like Puron®. - Has been approved for use in new residential air conditioners. - Is a hydro-fluorocarbon (HFC) which does not contribute to ozone depletion. - Will become the new required standard for U.S. residential air conditioning systems in 2015 - Can not be used in R22 designed systems. - Is low in price. - R-410A offers greater efficiency, saving you in energy costs, and is much better for the environment. What this means - - We can not determine if the system actually uses R22 or the low efficiency substitute R424A which may reduce system performance. - R22 systems are typically cost prohibitive to repair because of the high cost of R22 or R424A. - Older R22 refrigerant line-set (copper suction and liquid pipes) may require replacement when changing to R410a. - You may be forced to replace the R22 system in 2015. The typical course of action is to replace the Heat pump system with a modern R410 system. |
|
(5) Defect - Refrigerant line is poorly sealed and missing the protective rubber grommet at the plenum and is subject to rubbing on the knife edge of
the cabinet causing refrigerant leaks (Item 3). Have properly and professionally corrected as needed to ensure an air tight seal and to prevent
chaffing on the cabinet knife edge.
7.0 Picture 3
|
|
(6) Heat Pump Equipment Performance - The ambient air test was performed by using thermometers on the air handler of Heat pump in cool mode
to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is
cooling as intended. The supply air temperature on your system read 64 degrees (Item 4), and the return air temperature was 74 degrees (Item 5).
D/T = 10 Degrees F. This indicates that the system is
not functioning as designed and should be further evaluated and corrected as needed by a
qualified HVAC contractor.
7.0 Picture 4
7.0 Picture 5
|
|
(7) Deficiency - The insulation sleeve on suction line is missing at outside unit (Item 6). Missing insulation on suction line can cause energy loss and
condensation. Recommend maintenance repair as needed.
7.0 Picture 6
|
|
(8) Observation - The heat pump electric back up heat responds to testing. When tested in "emergency or auxiliary Heat" the output temperature
reading is 94 Degrees F. and is acceptable (Item 7).
7.0 Picture 7
|
|
(9) FYI - This home is heated and cooled with heat pump system. It is the same system and equipment that provides warm air in the winter and cool
air in the summer. When the outside temperature is below 60 deg. F. the system is tested in "heat" mode, When the outside temperature is above
60 deg.F. it is tested in the "cool" mode. Heat pumps can only be tested in Heat or Cool but not both.
Most heat pump systems contain auxiliary (emergency, back-up) heat, typically electric coils but can be gas or oil. This is always tested winter or summer for response. However, some electronic thermostats when in "cool" mode will not allow manual switching to axillary heat, in which case it can not be tested. |
7.1 |
PRESENCE OF INSTALLED AC/HP SOURCE AIR IN EACH ROOM
Comments and observations: Inspected |
7.2 |
NORMAL OPERATING CONTROLS
Comments and observations: Inspected |
7.3 |
DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments and observations: Inspected |
(1) Maintenance - The disposable return filter is clogged and is dirty (Item 1). The filter needs to be replaced. Note: a restricted return air filter can
cause reduced air flow, reduced efficiency and damage to equipment.
7.3 Picture 1
|
|
(2) Deficiency, Disclosure - This two story (2 zone) home has a shared duct system which means the ductwork runs through the ceiling joist downstairs which is also the flooring upstairs. It is a common duct that supplies both upstairs and downstairs heat and AC. The duct system is not zoned for each floor. There is no way to control the air flow and temperature levels equally on both floors. It will always be warmer upstairs and cooler down stairs year round. This is also compounded when there is only one return air grill for one of the floors or zones. Ideally there should be a return air grill for each floor. The comfort level will be determined by the zone that has the thermostat which is typically located close to the return grill. This is a common duct configuration in older homes but is no longer done in new construction because it degrades efficiency and comfort control. |
7.4 |
CHIMNEYS, FLUES AND VENTS (for fireplaces, water heaters or heat systems)
Comments and observations: Inspected |
Maintenance / Repair - The metal flashing cap at the top of framed wood chimney is rusting and deteriorating (Item 1). recommend preventative
maintenance and repairs before it fails and leaks.
7.4 Picture 1
|
7.5 |
SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove)
Comments and observations: Inspected |
GENERAL INSULATION CONDITION / RATING:
Fair ( Functional, some concerns, amateur work, maintenance/repairs needed, aging, worn.) |
Attic insulation:
neglegible Improvements recommended Loose or blown in fiberglass approx. R-13 fair |
Wall insulation:
concealed, not visible, not inspected |
Floor System Insulation:
N/A slab construction |
Bathroom steam vents:
Fan with light Fan |
Dryer Power Source:
220 Electric NOTE: This dryer outlet requires a 3 prong plug |
Dryer duct (built in):
Metal |
8.0 |
INSULATION IN ATTIC / CEILING
Comments and observations: Inspected |
(1) Defect - Observed missing insulation beneath the air handler overflow drain pan (Item 1). Recommend professional repairs be completed by a
qualified insulation contractor.
8.0 Picture 1
|
|
(2) Attic insulation thickness is marginal or substandard at R-13 but may have met typical requirements for the age of construction or it could have
settled or become packed down with storage. It does not meet the current standards or R factor of 38 which is recommended by the Department of
Energy. The attic or ceilings is where you'll loose (or gain) the most amount of heat transfer. Consideration should be given to upgrading. It is cost
effective and will increase the thermal efficiency of your home.
Visit these links and learn more about your homes insulation: See US Dept of Energy insulation consumer guide | See Insulation fact Sheet. | See Insulation calculator and estimators | Dept of Energy insulation zone map |
8.1 |
Wall insulation (if visible)
Comments and observations: Not Inspected |
8.2 |
INSULATION UNDER FLOOR SYSTEM
Comments and observations: Not Present |
8.3 |
VENTING SYSTEMS (Kitchens, baths and laundry)
Comments and observations: Inspected |
(1) Defect - The downstairs powder room steam vent exhaust duct is missing the exterior shroud and is subject to vermin infiltration and nesting (Item
1). Recommend professional repairs be completed by a qualified contractor using approved methods and materials.
8.3 Picture 1
|
|
(2) SAFETY ADVISORY- Dryer ducts should be cleaned and inspected annually for proper performance. Dryer ducts are susceptible to clogging and
blockage due to lint and moisture build up. Restricted dryer vents will not only reduce drying efficiency, but worse they can overheat and cause
fires.
If your dryer used a vinyl or foil flex duct connector you should dispose of it and replace with flexible aluminum duct. Aluminum duct is the most efficient type, safest type to reduce fire hazards and the only type recommended by dryer manufactures and by most municipal building codes. Dryer vent installation guidelines See more about dryer duct safety here. |
GENERAL APPLIANCE CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
GARBAGE DISPOSAL:
Functional |
DISHWASHER:
Functional |
RANGE/OVEN/STOVE/COOK TOP:
Functional |
MICROWAVE OVEN (built in):
None installed |
STOVE EXHAUST / RANGE HOOD:
Functional Not vented to exterior. Recirculate type. |
INDOOR DOWN DRAFT GRILL:
None installed |
TRASH COMPACTOR:
None installed |
9.0 |
DISHWASHER
Comments and observations: Inspected |
9.1 |
RANGES/OVENS/COOKTOPS
Comments and observations: Inspected |
Safety disclosure - The oven/range does not contain an anti-tip bracket and is subject to tipping when the door is opened and weight is placed on
the door (Item 1). According to the US CPSC (US Consumer Product Safety Commission) stoves without an anti-tip bracket or device can cause
injury or death, especially to small children (Item 2). Since 1991 it has been required that all electric and gas ranges have an anti-tip device
installed when the oven/range is installed (Item 3). This information is provided for your safety.
9.1 Picture 1
9.1 Picture 2
9.1 Picture 3
|
9.2 |
RANGE HOOD
Comments and observations: Inspected |
9.3 |
GARBAGE DISPOSAL UNIT
Comments and observations: Inspected |
Safety - The food disposer wiring is missing a romex connector (anti-strain device) (Item 1), wires are exposed which poses a shock/electrocution
hazard (Item 2). Recommend repairs be completed by an electrician.
9.3 Picture 1
9.3 Picture 2
|
9.4 |
MICROWAVE COOKING EQUIPMENT
Comments and observations: Not Present |