Home
Inspection Report
post purchase
|
||||||||
" We see what's missing " Final Analysis Home Inspections
| ||||||||
Prepared exclusively for Name removed for privacy |
||||||||
Becky Lane Chesapeake, VA 23322 |
||||||||
|
||||||||
|
||||||||
Report ID:
constant012507
|
||||||||
Inspection
Date: 1/25/2008
|
||||||||
Inspected By:
Dan Rogers
|
||||||||
757.495.2300 |
||||||||
Date: 1/25/2007 | Time: 1:00 PM | Report ID: constant012507 |
Property: Becky Lane Chesapeake, VA 23322 |
Customer: removed |
Real Estate Professional: |
Client Is Present: Yes | Age Of Home: 1989 | Weather: Clear |
Temperature: 46 | Rain in last 3 days: No | Square feet: 2600 |
Inspection type: Owner/Occupant | Structure type: 2 story single family residence | Occupancy: Property is occupied |
Reading this report - The report is broken down by each major system . At the beginning of each system section is an overview which describes what the inspector is required and not required to inspect (ASHI standards). The overview may also contain some general photos of that system. Then you will see the list the styles & materials identified for that system. Below that is the system components that are inspected. This is where the observations are reported along with any supporting photos. Also under each system component there is a general comment category which will contain one or more of the following: Satisfactory, Discrepant Item, Informational Disclosures, Maintenance Recommendations, Not Inspected.
Inspection issues or concerns are flagged and broken down to 3 categories: Defective (repair or replace), Informational Disclosures (environmental, material or safety concerns), Maintenance (recommended or preventative). Any problems that fall under these categories will also be listed in the General Summary and on the corresponding summary for that category. These itemized summaries help you quickly identify the nature of the problem and therefore your course of action.
Defect Summary - List of just Defects, Repair or Replace items.
Info, Safety & Disclosure Summary - List of just Safety issues and Informational Disclosures
Maintenance Summary - List of just Maintenance, issues, concerns and recommendations.
Overview: A thorough home inspection was completed at the subject property in accordance with ASHI standards. The inspection reveals that though this home has average wear for being 17 years old, its structure and systems are generally well built, maintained and in typical good repair. The type of items reported are typically found during all home inspections but should be reviewed and considered for correction as they are specific to this homes condition, safety and value.
GENERAL ROOF CONDITION: GOOD: Average condition& performance | ROOF INSPECTION LIMITATIONS: Typical inspection access | REMAINING SERVICE LIFE: 100% - New or Upgraded - No concern of replacement expense |
ROOF AS SEEN FROM: Ground Attic& Eaves Binoculars ladder | SYSTEM INSPECTED?: Yes | ROOF STYLES& DESIGN: Gable |
ROOF COVERING MATERIALS: ASPHALT: Architectural grade (higher quality) | FLASHING MATERIAL: Aluminum | SKY LIGHT (S): NONE |
ACTIVE ROOF OR FLASHING LEAKS: No | GUTTERS& DOWNSPOUTS: Attached:full Gutter Material: Aluiminum Splashblocks | ATTIC VENTILATION: Soffit Roof |
Layers of shingles: one |
1.0 | ROOF COVERINGS Comments - Satisfactory, Functional, Discrepant item, Repair or Replace | |
There appears to be some lifting of the shingles behind left area of chimney (difficult to see). Monitor and repair if needed. (Picture 1) |
1.1 | ROOF DECKING Comments - Satisfactory, Functional |
1.2 | FLASHING or JOINT MATERIALS Comments - Satisfactory, Functional, Discrepant item, Repair or Replace, Preventative maintenance recommended | |
Chimney flashing at rear of chimney is starting to separate. No leaks detected but a closure inspection should done in this area and provide repair maintenance if needed. (Picture 1) |
1.3 | GUTTERS, ROOF DRAINAGE SYSTEMS Comments - Satisfactory, Functional, Preventative maintenance recommended | |
Leaky seam at bay window gutter, Left corner. maintenance recommended. |
1.4 | SKYLIGHTS Comments - Not Present |
1.5 | VENTILATION Comments - Satisfactory, Functional |
GENERAL CONDITION: EXTERIOR: GOOD: Average condition& performance | SYSTEM INSPECTED?: Yes | EXTERIOR LIMITATIONS: Typical |
SIDING MATERIAL: VINYL | EXTERIOR TRIM: WOOD | PRIMARY WINDOWS: DOUBLE-HUNG GLAZING: THERMAL/INSULATED MATERIAL: PLASTIC/ VINYL |
EXTERIOR ENTRY DOORS: METAL | PORCHES AND OR DECKS: Wood Decking Masonry and/or raised slab porch | STEPS AND OR RAILS: MASONARY STEPS WOODEN STEPS WOODEN RAILS |
GARAGES AND OR CARPORTS: ATTACHED | FIRE ESCAPES: NONE NA | GARAGE AUTO OPENER: OVERHEAD DOOR Auto safety reverse test OK |
GARAGE DOOR MATERIAL: METAL | GARAGE DOOR TYPE: TWO AUTOMATIC | DRIVEWAY: CONCRETE |
2.0 | WALL CLADDING FLASHING AND TRIM Comments - Satisfactory, Functional |
2.1 | DOORS (Exterior) Comments - Satisfactory, Functional, Preventative maintenance recommended | |
Threshold seal is missing from bottom of rear entry door . ( Picture 1 ) |
2.2 | WINDOWS Comments - Preventative maintenance recommended | ||||
Paint failing and some wood rot detected in multiple areas of exterior roof trim, window trim and shutters. Maintenance is recommended. Inspect all exterior wood. Repair wood as needed and seal with paint.( Picture 1,2,3,4 ) |
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS Comments - Satisfactory, Functional, Informational notes and disclosures | |
(1) Safety - handrails are missing from deck steps. ( Picture 1 ) | ||
(2) SAFETY - Fence gate is not self closing. Should be self closing when accessing pool area to limit drowning hazzard.( Picture 2 ) |
2.4 | EAVES, SOFFITS, FASCIAS, RAKES, and EXTERIOR TRIM Comments - Satisfactory, Functional, Preventative maintenance recommended |
Paint is starting to fail in some areas of exterior trim. preventative maintenance is recommended. |
2.5 | DETACHED SHED Comments - Discrepant item, Repair or Replace | ||
Exterior shed is suffering from delayed maintenance. Observed paint failure, mildew on walls and rotten wood at base of doors. Paint and Repair as needed. ( Picture 1,2 ) |
2.6 | Garage door opener safety reverse Comments - Satisfactory, Functional |
GENERAL CONDITION: Foundation and Structure: GOOD: Average condition& performance | SYSTEM INSPECTED?: Yes | Crawlspace / Basement Water& Moisture conditions: No evidence of prior moisture problems Dry |
FOUNDATION/STRUCTURE LIMITATIONS: TYPICAL ACCESS | FOUNDATION TYPE: Crawlspace | STRUTURE AND MATERIALS: FRAME: WOOD FRAME: SILL FRAME: BAND FRAME: JOISTS FRAME: GIRDERS |
Foundation ventilation: FOUNDATION VENTS | INTERIOR DRAINAGE: VAPOR BARRIER Sand fill | EXTERIOR DRAINAGE: SITE: LEVEL Adequate |
METHOD USED TO OBSERVE CRAWLSPACE: CRAWLED LIMITED ACCESS | FLOOR STRUCTURE: 2 X 6 WOOD JOISTS | WALL STRUCTURE: WOOD 2 X 4 WOOD |
COLUMNS OR PIERS: MASONRY BLOCK | VIEWED ATTIC SPACE FROM:: WALKED | CEILING STRUCTURE: NOT VISIBLE |
ROOF STRUCTURE: 2 X 6 RAFTERS | ATTIC ACCESS: Pull down stairs | CRAWLSPACE: Garage access |
3.0 | FOUNDATION & STRUCTURE (Report signs of abnormal or harmful water penetration into the building or signs of abnormal settlement, structural failure, wood destroying insects & fungus.) Comments - Satisfactory, Functional |
3.1 | FOUNDATION VENTILATION & VAPOR BARRIER Comments - Discrepant item, Repair or Replace | ||
(1) Bricks and mortar are missing from around foundation vent, front left corner of house. ( Picture 1 ) | |||
(2) Vapor barrier is not 100% coverage ( Picture 2 ,3) which is the correct way. There is no evidence of a moisture problem in this crawlspace however there is some nominal dampness at left rear corner behind garage. Monitor this for future performance. |
3.2 | FLOORS (Structural) Comments - Satisfactory, Functional |
3.3 | WALLS (Structural) Comments - Satisfactory, Functional |
3.4 | COLUMNS OR PIERS Comments - Satisfactory, Functional |
3.5 | CEILINGS (structural) Comments - Satisfactory, Functional |
3.6 | ROOF STRUCTURE AND ATTIC Comments - Satisfactory, Functional |
3.7 | LOT& GRADING Comments - Satisfactory, Functional |
GENERAL SYSTEM CONDITION: plumbing: GOOD: Average condition& performance | SYSTEM INSPECTED?: Yes | Plumbing Limitations: Typically accessible areas |
Main water supply pipe (street service): POLYBUTYLENE (History of probelms) | Supply pipes and distribution materials ( visable ): COPPER | Waste Piping materials (visable): ABS |
Water pressure: adequate | Cross connects observed: Yes | Water supply system (potable): Public utility |
Waste system (sewage): Public sewage | Fixtures & faucets observed (checked for leaks & fill & drain function only): TUBS SINKS TOILETS SHOWERS | Hot water source: Gas (quicker recovery rate) 40 gallon tank |
REMAINING SERVICE LIFE of Water heater: 75% - Typical condition& minimal wear - No concern of replacement expense | Drainage at Fixtures: Adequate |
4.0 | INTERIOR DRAINS, SUPPLY PIPES, FIXTURES AND VENT SYSTEMS Comments - Satisfactory, Functional |
4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments - Informational notes and disclosures | |
Polybutylene plastic plumbing street supply line (PB) is installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Note: the main house does not have PB, just the street service pipe. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com |
4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments - Satisfactory, Functional |
4.3 | Fixtures Tubs and faucets Comments - Satisfactory, Functional, Preventative maintenance recommended | ||
Guest bath tub faucet and diverter valve is worn and leaky. maintenance and repair is recommended.( Picture 1 )
Cross connect observed where disposal water can backflow through dishwasher drain pipe. ( Picture 2 ) |
4.4 | MAIN WATER SHUT-OFF DEVICE (Describe location) Comments - Satisfactory, Functional |
Street meter valve. |
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Comments - Preventative maintenance recommended | ||
(1) Gas pipes are rusting and deteriorating. recommend preventative maintenance i.e.: wire brush and some rustoleum paint. | |||
(2) SAFETY - Copper lines used for natural gas piping, also no cut off valves installed. Copper lines are typically not allowed for use with natural gas service. There is also rust on the steel pipes. Have evaluated and repaired as needed by a plumbing/heating contractor. |
GENERAL SYSTEM CONDITION: Electrical: GOOD: Average condition& performance | ELECTRICAL LIMITATIONS: TYPICAL | EXTERIOR SERVICE AND METER: UNDER GROUND SERVICE |
SERVICE ENTRY WIRING: Aluminum 4/0 | INTERIOR COMPONENTS OBSERVED: RECEPTACLES SWITCHES LIGHT FIXTURES GFCI | EXTERIOR COMPONENTS OBSERVED: RECEPTACLES SWITCHES LIGHT FIXTURES |
MAIN PANEL(s) Type & Capacity: 150 AMP | BRANCH WIRE 15 and 20 AMP: COPPER | WIRING system & material: ROMEX |
Location of Main Panel: Garage |
5.0 | SERVICE ENTRANCE WIRING Comments - Satisfactory, Functional |
5.1 | MAIN SERVICE - Main panel, sub-panels, grounds & bonds, Capacities, Ratings, Overcurrent protection & distribution. Comments - Satisfactory, Functional |
5.2 | WIRING - Amperage & Voltage protection and compatibility of branch wiring & overcurrent devices, conductor material. ( breakers, fuses vs. size of conductors.) Comments - Satisfactory, Functional |
5.3 | EXTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. Comments - Satisfactory, Functional |
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. Comments - Discrepant item, Repair or Replace | |
(1) Safety defect - Open connections, unsecured electric box observed at attic fan.( Picture 1 ) | ||
(2) Improper switch in dinning room. Dinning room lights are on a 2 way circuit. This dimmer is a single switch and must be 3 way type to work properly from both entrances. ( Picture 2 ) |
5.5 | GFCI (ground fault circuit interrupts are safety outlets in "wet area" locations. i.e. baths, garage, exterior, kitchen, etc.) Comments - Satisfactory, Functional |
5.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS Comments - Satisfactory, Functional | |
Located in garage. |
5.7 | Smoke detectors Comments - Not Inspected |
GENERAL RATING: GOOD: Average condition& performance | LIMITS ON INSPECTION: TYPICAL | TYPE OF FUEL: HEAT PUMP (FORCED AIR) GAS |
EQUIPMENT LOCATION: Attic Garage Exterior | THERMOSTAT TYPE: MECHANICAL | THERMOSTAT LOCATION: Central hall Central room |
THERMOSTAT CONDITION: FUNCTIONAL | WARM AIR SYSTEMS: FURNACE(HOT AIR): UP FLOW | FIREPLACE/FLUES: MASONARY: WOOD BURNING Vented gas log appliance |
NUMBER OF HEAT SYSTEMS (excluding wood): TWO | HEAT SYSTEM BRAND: JANITROL | DUCTWORK: Insulated metal insulated flex duct |
FILTER TYPE: DISPOSABLE | OPERABLE FIREPLACES: ONE | NUMBER OF WOODSTOVES: NONE |
REMAINING SERVICE LIFE: 75% - Typical condition& minimal wear - No concern of replacement expense 0% - Maximum wear& tear - Aged - Budget for immediate replacement expense |
6.0 | HEATING EQUIPMENT Comments - Informational notes and disclosures, Preventative maintenance recommended | ||||
(1) 2 systems - downstairs garage 75000 BTUI gas furnace 1989( Picture 1,2 ) , upstairs 2 ton heat pump with 10 KW auxiliary heat 2004 ( Picture 3,4 )
------------------------------------------------------. Notice - Garage furnace (downstairs heat) is aging (1989)( Picture 1 ) and is near end of statistical service life. Budget for replacement in the near future. | |||||
(2) Garage furnace is very dirty, observed significant amount of dust and debris. service and maintenance is recommended by a qualified HVAC contractor.( Picture 2,3,4 ) | |||||
(3) SAFETY - Garage furnace does not contain a collision barrier to prevent vehicle impact.( Picture 5 ) |
6.1 | NORMAL OPERATING CONTROLS Comments - Satisfactory, Functional |
6.2 | CHIMNEYS, FLUES AND VENTS Comments - Discrepant item, Repair or Replace | |||
(1) SAFETY - Furnace flue is less than professional workmanship. Duct tape is used for connector which will fail against extreme heat. The flue pipe is also single wall type which gets extremely hot and can ignite combustible material.( Picture 1 ) Typically used is double wall insulated pipe. The furnace flue is also tied into the water heater flue which can cause back drafting. have evaluated and repaired as needed by an HVAC contractor. | ||||
(2) Evidence of possible chimney foundation rotation. ( Picture 4 ) This is when the weight of a masonry chimney causes it to tip or lean away from the structure. This one does not appear extreme. Monitor this for future movement. Observed separation at caulk lines that is tapered from top to base.( Picture 2,3 ). Consider having reviewed by a qualified structural contractor/engineer. |
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments - Discrepant item, Repair or Replace | |
(1) Observed branch duct crushed beneath larger return duct in the crawlspace near the center rear area of foundation. ( Picture 1 ) | ||
(2) Attic duct connections at plenum are starting to separate and leak air. have properly repaired as needed. |
6.4 | SPACE HEATING Comments - Not Present |
6.5 | GAS/LP FIRELOGS AND FIREPLACES Comments - Satisfactory, Functional |
6.6 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments - Satisfactory, Functional |
GENERAL RATING: GOOD: Average condition& performance | LIMITS ON THE INSPECTION: RESTRICTED: Weather is too cool to risk a run test. | EQUIPMENT LOCATION: Attic Garage Exterior |
THERMOSTAT TYPE: MECHANICAL | CONDITION OF THERMASTAT: FUNCTIONAL | THERMOSTAT LOCATION: see 6 heating/fireplace for thermostat |
COOLING EQUIPMENT TYPE: HEAT-PUMP CENTRAL ELECTRIC | DUCTWORK TYPE: INSULATED FLEXIBLE DUCT Shared with Heat system | FILTERS: DISPOSABLE |
COOLING EQUIPMENT ENERGY SOURCE: ELECTRICITY | CENTRAL AIR MANUFACTURER: JANITROL RHEEM | NUMBER OF A/C UNITS: TWO |
REMAINING SERVICE LIFE: 75% - Typical condition& minimal wear - No concern of replacement expense 0% - Maximum wear& tear - Aged - Budget for immediate replacement expense |
7.0 | COOLING AND AIR HANDLER EQUIPMENT Comments - Informational notes and disclosures, Preventative maintenance recommended | |||
Downstairs heat AC system equipment ( Picture 1 ) is aging (1989)( Picture 2 ) and at end of service life, budget for replacement in near future.
Refrigerant line insulation is missing from exterior line.( Picture 3 ) |
7.1 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments - Satisfactory, Functional |
See problems noted under heat system ductwork. |
7.2 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM Comments - Satisfactory, Functional |
7.3 | Normal Operating Controls, Thermostat Comments - Satisfactory, Functional |
GENERAL INSULATION RATING (subjective to age of home): GOOD: Average condition& performance | Insulation inspection limitations: TYPICAL | TYPE: FIBERGLASS |
ATTIC INSULATION: Loose or Blown FIBERGLASS | R- VALUE: APPROXIMATE R-19 | VENTILATION: SOFFIT VENTS Thermostatically controlled fan 8x8 Static Roof vents |
BATH EXHAUST FAN TYPES: FAN ONLY | FLOOR INSULATION: BATT FIBERGLASS | WALL INSULATION: UNKNOWN Little or no access - can't determine |
8.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) Comments - Satisfactory, Functional, Discrepant item, Repair or Replace | |||
Attic insulation is sub-standard. DOE recommends R19 (12 inches) in the attic. this is 6 inches R-19. Note the 2 x 6" joist exposed. ( Picture 1 ) Recommend adding more insulation.
Flooring insulation has fallen in several areas of crawlspace.( Picture 2,3 ) repair as needed. |
GENERAL RATING: GOOD: Average condition& performance | INTERIOR LIMITATIONS: TYPICAL RESTRICTED: Occupied with furniture | APPLIANCES: DISHWASHER RANGE BURNERS OVEN ELEMENTS HOOD FANS/VENTS MICROWAVE GARBAGE DISPOSER BATH/DRYER VENTS |
WALLS AND CEILING MATERIAL: DRYWALL | INTERIOR OF WINDOWS: Functional | RAILS AND STAIRS: HAINDRAILS SAFTEY RAILS STEPS |
FLOOR COVERING(S): CARPET TILE VINYL | INTERIOR DOORS: HOLLOW CORE WOOD | CABINETRY: WOOD |
COUNTERTOP: LAMINATE | DRYER VENT: UNKNOWN |
9.0 | CEILINGS Comments - Satisfactory, Functional |
9.1 | WALLS Comments - Satisfactory, Functional |
9.2 | FLOORS Comments - Satisfactory, Functional |
9.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments - Satisfactory, Functional |
9.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments - Satisfactory, Functional, Informational notes and disclosures | |
safety notice - Island cabinet is not secured to flooring. This is a potential tipping hazzard that can cause injury.. |
9.5 | DOORS (REPRESENTATIVE NUMBER) Comments - Satisfactory, Functional |
9.6 | WINDOWS (REPRESENTATIVE NUMBER) Comments - Satisfactory, Functional |
9.7 | INTERIOR INSPECTION ACCESSIBILITY Comments - Satisfactory, Functional |
9.8 | VENTING SYSTEMS (Kitchens, baths and laundry) Comments - Discrepant item, Repair or Replace | |
Microwave range exhaust is not connected to exterior ductwork. |
GENERAL RATING: GOOD: Average condition& performance | DISHWASHER: Functional | DISPOSER: Functional |
EXHAUST/RANGE HOOD: RE-CIRCULATE Not functional as designed or intended. | RANGE/OVEN: Functional | BUILT-IN MICROWAVE: Functional |
REFRIGERATOR: Personal property- not built in -NOT INSPECTED | DRYER POWER SOURCE: 22O ELECTRIC |
10.0 | DISHWASHER Comments - Satisfactory, Functional |
10.1 | RANGES/OVENS/COOKTOPS Comments - Satisfactory, Functional |
10.2 | RANGE HOOD Comments - Satisfactory, Functional |
10.3 | FOOD WASTE DISPOSER Comments - Satisfactory, Functional |
10.4 | MICROWAVE COOKING EQUIPMENT Comments - Satisfactory, Functional |
|
757-495-2300
|
Customer: removed Property Address: Becky Lane |
This General Summary is a combined list of any and all findings that where flagged during the inspection as important. The general summary contains all the items listed in the individual summaries below.
The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
KEY: Defects Safety & Disclosure info Maintenance
1.0 | ROOF COVERINGS | |
Satisfactory, Functional, Discrepant item, Repair or Replace | ||
There appears to be some lifting of the shingles behind left area of chimney (difficult to see). Monitor and repair if needed. (Picture 1) |
||
1.2 | FLASHING or JOINT MATERIALS | |
Satisfactory, Functional, Discrepant item, Repair or Replace, Preventative maintenance recommended | ||
Chimney flashing at rear of chimney is starting to separate. No leaks detected but a closure inspection should done in this area and provide repair maintenance if needed. (Picture 1) |
||
1.3 | GUTTERS, ROOF DRAINAGE SYSTEMS | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Leaky seam at bay window gutter, Left corner. maintenance recommended. |
2.1 | DOORS (Exterior) | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Threshold seal is missing from bottom of rear entry door . ( Picture 1 ) |
||
2.2 | WINDOWS | |
Preventative maintenance recommended | ||
Paint failing and some wood rot detected in multiple areas of exterior roof trim, window trim and shutters. Maintenance is recommended. Inspect all exterior wood. Repair wood as needed and seal with paint.( Picture 1,2,3,4 ) |
||
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
Satisfactory, Functional, Informational notes and disclosures | ||
(1) Safety - handrails are missing from deck steps. ( Picture 1 ) |
||
(2) SAFETY - Fence gate is not self closing. Should be self closing when accessing pool area to limit drowning hazzard.( Picture 2 ) |
||
2.4 | EAVES, SOFFITS, FASCIAS, RAKES, and EXTERIOR TRIM | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Paint is starting to fail in some areas of exterior trim. preventative maintenance is recommended. |
||
2.5 | DETACHED SHED | |
Discrepant item, Repair or Replace | ||
Exterior shed is suffering from delayed maintenance. Observed paint failure, mildew on walls and rotten wood at base of doors. Paint and Repair as needed. ( Picture 1,2 ) |
3.1 | FOUNDATION VENTILATION & VAPOR BARRIER | |
Discrepant item, Repair or Replace | ||
(1) Bricks and mortar are missing from around foundation vent, front left corner of house. ( Picture 1 ) |
4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
Informational notes and disclosures | ||
Polybutylene plastic plumbing street supply line (PB) is installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Note: the main house does not have PB, just the street service pipe. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com |
||
4.3 | Fixtures Tubs and faucets | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Guest bath tub faucet and diverter valve is worn and leaky. maintenance and repair is recommended.( Picture 1 )
Cross connect observed where disposal water can backflow through dishwasher drain pipe. ( Picture 2 ) |
||
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | |
Preventative maintenance recommended | ||
(1) Gas pipes are rusting and deteriorating. recommend preventative maintenance i.e.: wire brush and some rustoleum paint. |
||
(2) SAFETY - Copper lines used for natural gas piping, also no cut off valves installed. Copper lines are typically not allowed for use with natural gas service. There is also rust on the steel pipes. Have evaluated and repaired as needed by a plumbing/heating contractor. |
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
(1) Safety defect - Open connections, unsecured electric box observed at attic fan.( Picture 1 ) |
||
(2) Improper switch in dinning room. Dinning room lights are on a 2 way circuit. This dimmer is a single switch and must be 3 way type to work properly from both entrances. ( Picture 2 ) |
6.0 | HEATING EQUIPMENT | |
Informational notes and disclosures, Preventative maintenance recommended | ||
(1) 2 systems - downstairs garage 75000 BTUI gas furnace 1989( Picture 1,2 ) , upstairs 2 ton heat pump with 10 KW auxiliary heat 2004 ( Picture 3,4 )
------------------------------------------------------. Notice - Garage furnace (downstairs heat) is aging (1989)( Picture 1 ) and is near end of statistical service life. Budget for replacement in the near future. |
||
(2) Garage furnace is very dirty, observed significant amount of dust and debris. service and maintenance is recommended by a qualified HVAC contractor.( Picture 2,3,4 ) |
||
(3) SAFETY - Garage furnace does not contain a collision barrier to prevent vehicle impact.( Picture 5 ) |
||
6.2 | CHIMNEYS, FLUES AND VENTS | |
Discrepant item, Repair or Replace | ||
(1) SAFETY - Furnace flue is less than professional workmanship. Duct tape is used for connector which will fail against extreme heat. The flue pipe is also single wall type which gets extremely hot and can ignite combustible material.( Picture 1 ) Typically used is double wall insulated pipe. The furnace flue is also tied into the water heater flue which can cause back drafting. have evaluated and repaired as needed by an HVAC contractor. |
||
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
Discrepant item, Repair or Replace | ||
(1) Observed branch duct crushed beneath larger return duct in the crawlspace near the center rear area of foundation. ( Picture 1 ) |
7.0 | COOLING AND AIR HANDLER EQUIPMENT | |
Informational notes and disclosures, Preventative maintenance recommended | ||
Downstairs heat AC system equipment ( Picture 1 ) is aging (1989)( Picture 2 ) and at end of service life, budget for replacement in near future.
Refrigerant line insulation is missing from exterior line.( Picture 3 ) |
8.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | |
Satisfactory, Functional, Discrepant item, Repair or Replace | ||
Attic insulation is sub-standard. DOE recommends R19 (12 inches) in the attic. this is 6 inches R-19. Note the 2 x 6" joist exposed. ( Picture 1 ) Recommend adding more insulation.
Flooring insulation has fallen in several areas of crawlspace.( Picture 2,3 ) repair as needed. |
9.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | |
Satisfactory, Functional, Informational notes and disclosures | ||
safety notice - Island cabinet is not secured to flooring. This is a potential tipping hazzard that can cause injury.. |
||
9.8 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
Discrepant item, Repair or Replace | ||
Microwave range exhaust is not connected to exterior ductwork. |
|
757-495-2300
|
Customer: removed Property Address: Becky Lane |
This section is a summary list of defective components, systems, or workmanship that may need repair or replacement in order to restore to intended function or to a level of what's considered "good repair".
1.0 | ROOF COVERINGS | |
Satisfactory, Functional, Discrepant item, Repair or Replace | ||
There appears to be some lifting of the shingles behind left area of chimney (difficult to see). Monitor and repair if needed. (Picture 1) |
||
1.2 | FLASHING or JOINT MATERIALS | |
Satisfactory, Functional, Discrepant item, Repair or Replace, Preventative maintenance recommended | ||
Chimney flashing at rear of chimney is starting to separate. No leaks detected but a closure inspection should done in this area and provide repair maintenance if needed. (Picture 1) |
2.5 | DETACHED SHED | |
Discrepant item, Repair or Replace | ||
Exterior shed is suffering from delayed maintenance. Observed paint failure, mildew on walls and rotten wood at base of doors. Paint and Repair as needed. ( Picture 1,2 ) |
3.1 | FOUNDATION VENTILATION & VAPOR BARRIER | |
Discrepant item, Repair or Replace | ||
(1) Bricks and mortar are missing from around foundation vent, front left corner of house. ( Picture 1 ) |
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | |
Preventative maintenance recommended | ||
(2) SAFETY - Copper lines used for natural gas piping, also no cut off valves installed. Copper lines are typically not allowed for use with natural gas service. There is also rust on the steel pipes. Have evaluated and repaired as needed by a plumbing/heating contractor. |
5.4 | INTERIOR - wiring, polarity & grounding of fixtures, receptacles and connected devices. | |
Discrepant item, Repair or Replace | ||
(1) Safety defect - Open connections, unsecured electric box observed at attic fan.( Picture 1 ) |
||
(2) Improper switch in dinning room. Dinning room lights are on a 2 way circuit. This dimmer is a single switch and must be 3 way type to work properly from both entrances. ( Picture 2 ) |
6.2 | CHIMNEYS, FLUES AND VENTS | |
Discrepant item, Repair or Replace | ||
(1) SAFETY - Furnace flue is less than professional workmanship. Duct tape is used for connector which will fail against extreme heat. The flue pipe is also single wall type which gets extremely hot and can ignite combustible material.( Picture 1 ) Typically used is double wall insulated pipe. The furnace flue is also tied into the water heater flue which can cause back drafting. have evaluated and repaired as needed by an HVAC contractor. |
||
$2,501 - $5,000 | ||
(2) Evidence of possible chimney foundation rotation. ( Picture 4 ) This is when the weight of a masonry chimney causes it to tip or lean away from the structure. This one does not appear extreme. Monitor this for future movement. Observed separation at caulk lines that is tapered from top to base.( Picture 2,3 ). Consider having reviewed by a qualified structural contractor/engineer. |
||
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
Discrepant item, Repair or Replace | ||
(1) Observed branch duct crushed beneath larger return duct in the crawlspace near the center rear area of foundation. ( Picture 1 ) |
8.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | |
Satisfactory, Functional, Discrepant item, Repair or Replace | ||
Attic insulation is sub-standard. DOE recommends R19 (12 inches) in the attic. this is 6 inches R-19. Note the 2 x 6" joist exposed. ( Picture 1 ) Recommend adding more insulation.
Flooring insulation has fallen in several areas of crawlspace.( Picture 2,3 ) repair as needed. |
9.8 | VENTING SYSTEMS (Kitchens, baths and laundry) | |
Discrepant item, Repair or Replace | ||
Microwave range exhaust is not connected to exterior ductwork. |
|
757-495-2300
|
Customer: removed Property Address: Becky Lane |
This section is a summary list of informational disclosures. These items may not be considered an obvious or repairable defect but may be an inherent problem to the home. They are listed here as they may have important consequences regarding your purchase. The items listed here are typically safety issues, environmental concerns, Antiquated systems and equipment, Building material/systems manufacturer deficiencies or recalls.
2.3 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
Satisfactory, Functional, Informational notes and disclosures | ||
(1) Safety - handrails are missing from deck steps. ( Picture 1 ) |
||
(2) SAFETY - Fence gate is not self closing. Should be self closing when accessing pool area to limit drowning hazzard.( Picture 2 ) |
4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
Informational notes and disclosures | ||
Polybutylene plastic plumbing street supply line (PB) is installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Note: the main house does not have PB, just the street service pipe. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com |
6.0 | HEATING EQUIPMENT | |
Informational notes and disclosures, Preventative maintenance recommended | ||
(1) 2 systems - downstairs garage 75000 BTUI gas furnace 1989( Picture 1,2 ) , upstairs 2 ton heat pump with 10 KW auxiliary heat 2004 ( Picture 3,4 )
------------------------------------------------------. Notice - Garage furnace (downstairs heat) is aging (1989)( Picture 1 ) and is near end of statistical service life. Budget for replacement in the near future. |
||
(3) SAFETY - Garage furnace does not contain a collision barrier to prevent vehicle impact.( Picture 5 ) |
7.0 | COOLING AND AIR HANDLER EQUIPMENT | |
Informational notes and disclosures, Preventative maintenance recommended | ||
Downstairs heat AC system equipment ( Picture 1 ) is aging (1989)( Picture 2 ) and at end of service life, budget for replacement in near future.
Refrigerant line insulation is missing from exterior line.( Picture 3 ) |
9.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | |
Satisfactory, Functional, Informational notes and disclosures | ||
safety notice - Island cabinet is not secured to flooring. This is a potential tipping hazzard that can cause injury.. |
|
757-495-2300
|
Customer: removed Property Address: Becky Lane |
This section is a summary of maintenance needed or preventative maintenance recommended in order to maintain a level of "good repair".
1.2 | FLASHING or JOINT MATERIALS | |
Satisfactory, Functional, Discrepant item, Repair or Replace, Preventative maintenance recommended | ||
Chimney flashing at rear of chimney is starting to separate. No leaks detected but a closure inspection should done in this area and provide repair maintenance if needed. (Picture 1) |
||
1.3 | GUTTERS, ROOF DRAINAGE SYSTEMS | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Leaky seam at bay window gutter, Left corner. maintenance recommended. |
2.1 | DOORS (Exterior) | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Threshold seal is missing from bottom of rear entry door . ( Picture 1 ) |
||
2.2 | WINDOWS | |
Preventative maintenance recommended | ||
Paint failing and some wood rot detected in multiple areas of exterior roof trim, window trim and shutters. Maintenance is recommended. Inspect all exterior wood. Repair wood as needed and seal with paint.( Picture 1,2,3,4 ) |
||
2.4 | EAVES, SOFFITS, FASCIAS, RAKES, and EXTERIOR TRIM | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Paint is starting to fail in some areas of exterior trim. preventative maintenance is recommended. |
3.1 | FOUNDATION VENTILATION & VAPOR BARRIER | |
Discrepant item, Repair or Replace | ||
(2) Vapor barrier is not 100% coverage ( Picture 2 ,3) which is the correct way. There is no evidence of a moisture problem in this crawlspace however there is some nominal dampness at left rear corner behind garage. Monitor this for future performance. |
4.3 | Fixtures Tubs and faucets | |
Satisfactory, Functional, Preventative maintenance recommended | ||
Guest bath tub faucet and diverter valve is worn and leaky. maintenance and repair is recommended.( Picture 1 )
Cross connect observed where disposal water can backflow through dishwasher drain pipe. ( Picture 2 ) |
||
4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | |
Preventative maintenance recommended | ||
(1) Gas pipes are rusting and deteriorating. recommend preventative maintenance i.e.: wire brush and some rustoleum paint. |
6.0 | HEATING EQUIPMENT | |
Informational notes and disclosures, Preventative maintenance recommended | ||
(2) Garage furnace is very dirty, observed significant amount of dust and debris. service and maintenance is recommended by a qualified HVAC contractor.( Picture 2,3,4 ) |
||
6.3 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | |
Discrepant item, Repair or Replace | ||
(2) Attic duct connections at plenum are starting to separate and leak air. have properly repaired as needed. |
7.0 | COOLING AND AIR HANDLER EQUIPMENT | |
Informational notes and disclosures, Preventative maintenance recommended | ||
Downstairs heat AC system equipment ( Picture 1 ) is aging (1989)( Picture 2 ) and at end of service life, budget for replacement in near future.
Refrigerant line insulation is missing from exterior line.( Picture 3 ) |
|
INVOICE |
Final Analysis Home Inspections
757-495-2300 Inspected By: Dan Rogers |
Inspection Date: 1/25/2007
Report ID: csnt012507 |
Customer Info: | Inspection Property: |
removed
Becky Lane |
Becky Lane Chesapeake, VA 23322 |
Inspection Fee:
| ||||||||
Tax $0.00 | ||||||||
Total Price $285.00 |
Payment Method:Check
Payment Status:Paid At Time Of Inspection
Note:Check # 468, Thank you!
Final Analysis 757-495-2300 |